FLP05 10kA with failure indicator surge suppressors

FLP05
FATECH FLP05-i series consist of FLP05-150i-P/BG, FLP05-150i-S/BG, FLP05-275i-P/BG, FLP05-275i-S/BG, FLP05-320i-P/BG, FLP05-320i-S/BG, FLP05-385i-P/BG and FLP05-385i-S/BG, which are Class II+III/C+D/T2+T3 combined surge protective devices dedicated for LED street light systems.
Applicable to 120V, 230V and 380V outdoor LED lighting networks, this series features rated continuous operating voltages of 150V, 275V, 320V and 385V. It delivers a maximum discharge current of 10kA and a nominal discharge current of 5kA, with excellent voltage protection levels for L‑N, N‑PE and L‑PE circuits to suppress transient overvoltage efficiently.The response time reaches ≤25ns for L-N and ≤100ns for N-PE, equipped with internal thermal cut-off and a 16A recommended backup fuse. Different from the standard FLP05 version, this i-type model is equipped with an LED failure indicator to intuitively display the working status and fault conditions in real time.
With IP66 high waterproof and dustproof performance, UL94V-0 flame retardant housing, wide operating temperature of -40°C~+80°C and maximum applicable altitude of 3000m, it ensures long-term stable operation in harsh outdoor environments. It is an ideal status-monitorable surge protection solution for LED street lights, outdoor landscape lighting and municipal lighting projects.

-New designed surge protection module for LED street light. with LED failure indicator.

-specifically for outdoor and commercial LED lighting applications, LED signage and traffic light manufacturers,including roadway lighting, parking garage lighting, wash wall lighting,traffic lighting, flood lighting, digital signage,street lightning, and tunneal lighting.

-Imax 10kA lightning surge protection.

-Metal oxide varistor (MOV) thermal protection.

-Water proof IP64.

Advantage

Stable & Reliable Surge Protection

Stable & Reliable Surge Protection

Adopts high-quality core components and precise circuit design, providing stable and consistent performance to effectively suppress lightning surges and transient overvoltage, ensuring long-term safe operation of equipment.
Adopts high-quality core components and precise circuit design, providing stable and consistent performance to effectively suppress lightning surges and transient overvoltage, ensuring long-term safe operation of equipment.

Adopts high-quality core components and precise circuit design, providing stable and consistent performance to effectively suppress lightning surges and transient overvoltage, ensuring long-term safe operation of equipment.

Covers AC, DC, photovoltaic, PoE network, and signal surge protection solutions, widely used in solar systems, LED lighting, industrial control, security monitoring, buildings and infrastructure.
Durable Structure & Easy Installation

Durable Structure & Easy Installation

Durable Structure & Easy Installation
Certified Quality & Cost-Effective

Certified Quality & Cost-Effective

Most core products have passed TUV, CE and international safety certifications, with strict quality control. Stable performance and reasonable pricing bring high cost-performance for global projects.

FLP05-150i-P/BG

FLP05-150i-S/BG

UN : 120V

UC : 150V

Imax:10kA

In:5kA

FLP05-275i-P/BG

FLP05-275i-S/BG

UN : 230V

UC : 275V

Imax:10kA

In:5kA

FLP05-320i-P/BG

FLP05-320i-S/BG

UN : 230V

UC : 320V

Imax:10kA

In:5kA

FLP05-385i-P/BG

FLP05-385i-S/BG

UN : 380V

UC : 385V

Imax:10kA

In:5kA

Coding of FLP05

Dimension of  FLP05

Circuit of FLP05

Electrical parameters

Model. No. FLP05-150i-P/BG
FLP05-150i-S/BG
FLP05-275i-P/BG
FLP05-275i-S/BG
FLP05-320i-P/BG
FLP05-320i-S/BG
FLP05-385i-P/BG
FLP05-385i-S/BG
Test class IEC/EN/VDE Class II+III/C+D/T2 T3
Type of Network LED street light
Nominal voltage 50(60)Hz UN 120V 230V 230V 380V
Rated Voltage (Max. Cont. Operating Voltage) Uc 150V 275V 320V 385V
Max. discharge current (8/20us)Imax 10kA
Nominal discharge current (8/20us) In 5kA
Voltage protective level Up L-N ≤0.8kV ≤1.1kV ≤1.3kV ≤1.5kV
N-PE ≤0.5kV ≤0.5kV ≤0.6kV ≤1.0kV
L-PE ≤1.0kV ≤1.3kV ≤1.5kV ≤1.7kV
Open circuit voltage Uoc 10kV
Response time tA L-N:≤25ns,N-PE:≤100ns
Recommended back-up fuse 16A
Thermal Cut-off Member Internal
Protection Mode L-N,N-PE,L-PE
Operation temperature range/altitude -40°C~+80°C /3000m
Degree of protection IP66
Housing material UL94V-0

Searching For A Reliable SPD & Surge Protector To Secure Your Projects?

MOQ is flexible and can be negotiated. Depending on your system solution, Accept Customization for Small Orders. Design products as your specification. Professional protection and stable performance for global projects. Submit an online message. Reply within 24 hours by email.

Why Send Us An Inquiry?

  • Professional SPD & lightning surge protection solutions
  • Custom design for your project & small MOQ supported
  • Certified quality & factory direct price
  • Quick technical support & quotation
  • Response in 24 hours