Introduction of Fatech LED street light surge protection module
Fatech Surge Protector is widely used for surge protection of street lighting, traffic lighting, packing garage lighting, digital signage, wash wall lighting, tunnel lighting, roadway lighting, and flood lighting.
1. Surge protection scheme for LED sreet lighting is as below,
1) Circuit breaker is installed in the distribution box of the lamp club seat—for overcurrent protection
2) Surge protector with thermal protection—for over-voltage protection
3) Drive power with current protection—for over-current protection


2. Fatech LED street lighting surge protector overview,
1) Protection module maximum LightningSurge current
– FLP10 Series – 20kA
– FLP05 Series – 10kA
2) Thermally protected Varistor technology
3) Parallel connected and series connected SPD options
4) IP66 water-proof and dust-proof
5) Compact form factor with mounting tabs
6) Working status indictor for your option
7) DIN rail style for your option
3. Technical Prameter
1) FLP05-D: DIN rail type LED street light SPD

2) FLP05-xxx-x: 10kA/10kV & FLP10-xxx-x: 20kA/20kV surge protector for LED street lighting


4. Features and benefits to use FATECH surge protector for LED street lighting

1). Maximum Lightning Surge Current 20kA
Optimized surge immunity solution to protect the outdoor LED fixture investment to get the long term reduction in maintenance costs and energy savings. Without surge protection, the value proposition of LED lighting is at risk
2). Thermally protected varistor
Thermal fail-safe protection to prevent a hazard to the light or facility due to ‘end-of-life’ or extreme failure conditions of internal components
3). No Leakage and no streaming technology
Unique MOV and GDT series connected technology, to improve the using life of SPD
4). Full protection mode
Well-designed MOV components, can achieve the mode of common protection and differential protection, safe and realibe
5).Wide operation voltage 120Vac~480Vac
Flexibility to select optimal protection for each lighting installation input voltage
6). Ingress protection IP66
Surge protector is less susceptible to damage from water or environment
7). Series connected and parallel connected SPD options
Series – Clear indication for SPD module replacement by turning luminaire off when the thermal fail-safe protection is activated

Parallel – External wire option for LED indication or adaptive lighting circuit

5. Application